Category Archives: Windows - Page 9

Where can I download the unzip utility for Windows?

Where can I download the unzip utility for Windows?

https://updates.oracle.com/unzips/unzips.html

http://www.info-zip.org/

cl.exe – Unable To Locate Component

Problem:

After installing Microsoft Visual Studio 2005, placed the bin directory (D:MSVSVCbin) in the PATH environment variable. Then ran cl.exe. The following message appeared:

cl.exe - Unable To Locate Component
This application has failed to start because mspdb80.dll was not found. 
Re-installing the application may fix this problem.

Solution:

Search for the following files:

msobj80.dll
mspdb80.dll
mspdbcore.dll
mspdbsrv.exe

They are under D:MSVSCommon7IDE.

Copy and paste them to the folder containing “cl.exe” (D:MSVSVCbin).

Reference:

http://connect.microsoft.com/VisualStudio/feedback/details/553848/mspdb80-dll-was-not-found

602-Diskette Boot Record Error

Problem:

When rebooting an HP ML350 G3 server, the following message appears on the screen:

602-Diskette Boot Record Error

This message appears while starting up before checking the CD, so I am unable to boot into the Windows Installation CD to repair the system.

Solution:

Remove attached external hard drive from the server and reboot.

RW-50004: Error code received when running external process

Problem:

When installing an E-Business Suite R12 Vision instance, the following error appears:

RW-50004: Error code received when running external process. Check log file for details.
Running APPL_TOP Install Driver for VIS12 instance

Step 3 of 5
Command: G:oracleVIS12instappsVIS12_appswindows2tempadrunias.cmd
53%
Registering Applications Technology Stack
92%

Solution:

2. In $INST_TOP/temp/restart.xml, change line:

FROM:

<installprocess oa_var="s_rerunprocess">"runProcess_1"</installprocess>

TO:

<installprocess oa_var="s_rerunprocess">runProcess_1</installprocess>

Use restart option to retry the installation.

Read more »

RW-50004: Error code received when running external process

RW-50004: Error code received when running external process

Problem:

When installing R12 (Vision instance) on Windows Server 2003 Standard Edition, the following error occurs:

RW-50004: Error code received when running external process. Check log file for details.
Running APPL_TOP Install Driver for VIS12 instance

Solution:

Edit $INST_TOP/temp/restart.xml and change “runProcess_2” to runProcess_2.
Read more »

Installation Checklist for R12 on Windows 2003

Installation Checklist for R12 on Windows Server 2003 Standard Edition

Here are the steps I took while installing R12.1 Vision instance on Windows:

1. Install Windows Server 2003 Standard Edition on 30GB C: partition
2. Allocate static IP address for network connection and put entry into hosts file
3. Install Windows Server 2003 Service Pack 2
4. Apply additional downloaded Windows updates from Microsoft
5. Create D: drive for downloads and additional applications
6. Create F: drive for database (146GB)
7. Create G: drive for EBS applications (146GB)
8. Ran ScanDisk on D: and F: (taking very long)
9. Installed Microsoft Visual Studio 2005 to D:MSVS (installed XML and Visual C, disabled all other applications).
10. Install Visual Studio 2005 Service Pack 1 ATL Security Update [ID 761567.1]
11. Add D:MSVSVCbin to PATH environment variable (in My Computer > Properties)
12. Downloaded gnumake fro MOS (patch 5897842) and unzipped [ID 761567.1]
13. Installed Cygwin to D:cygwin (downloaded all packages to local disk D:cygwin-install, then installed all packages to D:cygwin). [ID 414992.1]
14. Copied make-3.81WinRelgnumake.exe to D:cygwinbin [ID 414992.1]
15. Add D:cygwinbin to PATH environment variable (in My Computer > Properties) [ID 414992.1]
16. In D:cygwinbin, renamed make.exe to _make.exe and copied gnumake.exe to make.exe
17. Rename Cygwin’s rmdir executable (rmdir.exe) to _rmdir.exe [ID 414992.1]
18. In D:cygwinbin, renamed link.exe to _link.exe [ID 761567.1]
19. Staged R12.1 CDs to D:StageR12
20. Downloaded latest StartCD R12.1.1 startCD – RAPID INSTALL STARTCD 12.1.1.13 (patch 11072566) [ID 798258.1]
21. In D:StageR12, renamed startCD to _startCD and unzipped patch 11072566 into this D:StageR12 to create new startCD
22. Opened Command Prompt and ran D:StageR12startCDDisk1rapidwizrapidwiz.cmd

Parameters

New Configuration: Create a new configuration
Port Pool Number: 12
Database Type: Vision Demo Database
Database SID: VIS12
Host Name: appswindows2
Domain Name: domainname.com
Operating System: Windows (32-bit)
Database OS User: Administrator
(Database Node) Base directory: F:oracleVIS12
Data Top (ARCHIVE): G:oracleVIS12dbapps_stdata
UNIX Toolkit directory: D:cygwinbin
Visual Studio directory: D:MSVSVC
(Applications Node) Base Directory: G:oracleVIS12
(Applications Node) Instance Directory: G:oracleVIS12inst

Errors

1. If you encounter the following error:

RW-50004: Error code received when running external process. Check log file for details.
 Running APPL_TOP Install Driver for VIS12 instance

Edit $INST_TOP/temp/restart.xml and change “runProcess_2” to runProcess_2. Remember to kill the running Oracle Universal Installer before clicking Retry.

2. FRM-92050: Failed to connect to the Server: /forms/lservlet:-1

3. In Step 1 of 5

RC-00110: Fatal: Error occurred while relinking of ApplyDBTechStack

 

Log Files

Configuration file written to: G:oracleVIS12instappsVIS12_appswindows2conf_VIS12.txt
Configuration file written to: F:oracleVIS12dbtech_st11.1.0appsutilconf_VIS12.txt

Configuration file written to: G:oracleVIS12instappsVIS12_appswindows2conf_VIS12.txt
Configuration file written to: F:oracleVIS12dbtech_st11.1.0appsutilconf_VIS12.txt
Database logfile – F:oracleVIS12dbtech_st11.1.0appsutillogVIS12_appswindows29121000.log
Appltop logfile – G:oracleVIS12instappsVIS12_appswindows2logs9121000.log
Appltop logfile – G:oracleVIS12instappsVIS12_appswindows2logs9121000.log

Reference

Oracle E-Business Suite Installation and Upgrade Notes Release 12 (12.1.1) for Microsoft Windows Server (32-bit) [ID 761567.1]

Using Cygwin to Maintain Oracle E-Business Suite Release 12 on Windows [ID 414992.1]

Oracle Applications Documentation Resources, Release 12.1 [ID 790942.1]

How to Remove an Oracle E-Business Suite Release 12.x Windows Environment [ID 567507.1]

ORACLE error 20100 in FDPSTP

Problem: When running the Payments batches process in Oracle, the following error occurs.

ORACLE error 20100 in FDPSTP 

Cause: FDPSTP failed due to ORA-20100: File o}|#{|.tmp creation for FND_FILE failed. 
You will find more information on the cause of the error in request log. 
ORA-06512: at "APPS.FND_FILE", line 396 ORA-06512.

Solution: Free disk space.

The drive on which temp files were created (pointed to by %TEMP% or %TMP%) ran out of space. Clear some disk space, and then rerun the Payments batches process.

 

THE SITE BOOTED WITH INTERNAL DEFAULT SETTINGS, BECAUSE OF: bea.jolt.ServiceException: Invalid Session

Problem: When PeopleSoft is launched (http://appswindows.domainname.com:8000/psp/fsdmo/?cmd=login&languageCd=ENG&), the PeopleSoft login page appears and the following error is displayed:

CHECK APPSERVER LOGS. THE SITE BOOTED WITH INTERNAL DEFAULT SETTINGS,
BECAUSE OF: bea.jolt.ServiceException: Invalid Session

Solution: Change the value of the psserver variable in the configuration.properties file from machine name to IP address.

Read more »

11i Pre Patching Script

Problem: How can I minimize errors occurring while patching on the Windows platform?

Solution: Use a script to ensure that all environment variables are set and all supporting utilities are accessible.

Read more »

Installing FSCM 9.0 PeopleBooks for SQL Server on Windows

Problem: Procedure for installing PeopleBooks for Financials/Supply Chain Management (FSCM) 9.0 unclear.

Solution:

The documentation for installing PeopleBooks is available in the PeopleTools Installation guide. In this case, FSCM 9.0 was installed on PeopleTools 8.49 on the Microsoft SQL Server database.

Read more »