Errors while running createvw.dms:
Related language record RE_LANDLORD_LG used by record RE_LANDLORD not found. (20,52) Related Language Record VCHR_SRCHLG1_VW used by VCHR_SRCHCRT_VW not found (20,52) Related language record BI_SHP_LANG_VW used by record BI_SHP_ADDR_VW2 not found. (20,52)
Data Mover crashes out.
Solution:
Did not perform step 10 of the PT 8.49.15 Product Patch User Documentation (https://psft-updates.oracle.com/ice/Resolutions/768890/PT84915UserDoc_rev2.htm). Using Application Designer, log on as user VP1 and copy project PATCH849. Then, in Data Mover, log on as VP1 and rerun CREATEVW.DMS.
10. Copy Patch Project – ONLY if PATCH849 exists –
Note: If no database changes have been made in PT 8.49 by the time this patch is released, the PATCH849 project will not exist in the projects folder and this step can be ignored.
a. Using PeopleTools 8.49.15, launch Application Designer, and sign on to the database as a PeopleSoft User. [VP1]
b. Select Tools > Copy Project > From File
c. Enter projects and select PATCH849 from the list of projects
d. Select Options and highlight the languages Common and English ONLY.
e. Select Copy to begin copying updated PeopleTools objects to your database.
After rerunning CREATEVW.DMS, the last four lines of the CREATEVW.LOG file shows:
SQL Views: 27267
Ended: Wed Dec 17 18:23:25 2008
Successful completion
Script Completed.
Other steps to try:
Stop SQL Server services and restart.
Log on as user VP1 when running createvw.dms
Reference:
http://www.pinpointps.com/?q=node/59
Restarting data mover after a crash
A data mover script can be restarted by coding in the DMS ‘set start after record name’ before the Import * command. If the record is name ps_tablename, then do not code the ‘ps_’, just code tablename.
Attempted to create views using Application Designer: In Application Designer, click Ctrl+F7 (Insert > Definitions from Project…), and search for all Records. Select All records and insert them into the current project (takes about 10 minutes to complete). Then click Build > Project and check only Create Views (modify other settings as necessary). Build the SQL script, and after creating,
Recent Comments